| general |  automotive |  petroleum |  medical devices |  aerospace | 

 
19348 Londelius Street
Northridge, CA 91324

Toll Free:
800.423.1701
818.349.5690

Fax
818.717.8584
 

Equipment Sales


HLT 560 hydrogen and helium Leak detector

This Helium Leak detector is simple, user-friendly operation. Only Start/Stop and Zero are required for standard operation, Menu driven, operating unit and remote control in one unit.

Flapper Boxes

Features:

  • Spring loaded, hinged top for rapid loading of test specimens
  • Standard connection flange: KF-25 (1 inch quick flange)
  • Designed for testing of hermetically sealed test specimens to MIL-STD 202 and 750
  • Available in Aluminum and Stainless Steel
  • Standard Cavity Sizes:
    2.275 in. .75 in.
    4.375 in. 1.50 in.
    5.375 in. 2.00 in.
  • Larger size available upon request.
  • Alternate connection flanges available upon request.

 

 

Helium Spray Gun/Nozzle for leak testing applications

Features:

  • User friendly
  • Complete and ready for use
  • Connection to Regulator supplied
  • Adjustable Helium Flow
  • Pitol grip w/ trigger On/Off action
  • Non-Invasive Tip
  • 10 ft. flexible hose standard
  • Longer hose lengths available
  • 1/4" NPT Adapter Supplied

 

 

HLT Pressurizing Helium Bomb Chamber

Features:

  • 2 1/2 Gallon Capacity (.3125 cubic feet)
  • 30 inch/0-75 PSIG Combination Gauge
  • Individual pressure and Evacuation Valves (1/4 NPT)
  • MIL-STD-202 / 750 Applications
  • Rated for 30 inch Vacuum and 50 PSIG Pressure
  • Portable

 

 

 

Pyrex Glass Bell jar

Features:

  • Dimensions - 12x12 Inch
  • Pyrex Glass
  • W/ Gasket
  • Scatter Shield and Base Plates available upon request

 

 

 

Q196 Leak Detector

Features:

  • Sensitivity - Helium - 1x10 -5cc/sec
  • R12 - 8x10 -3cc/sec
  • CO2 - 1x1- -4 cc/sec
  • Ar   - 1x10-4 cc/sec
  • User friendly
  • Display Units - cc/sec, cc/min, cu. ft./ min, PPM
  • Small, Robust and extremely portable
  • Response Time -< 1 second
  • Operating Time - 9 hours per charge
  • Recharge Time - 19 hours from total discharge
  • Probe Length - 5 Ft
  • Dimensions - Hand Unit : 3inx7inx1in Carrying Case 3in x 10in x 14'
  • Weight - 1lb. 3.5 lbs.

Automated System: Multi-port Leak Detector System

Computer Controlled System

The multi-port system purpose is to leak check double enclosure pipe interconnections. This system was designed to accommodate more than twenty different configurations per customer request. Exchanging fixtures is fast and simple. A complete fixture exchange and qualification would take no more than 10 minutes. The added value of this system to our customer besides the ability able to enhance sensitivity for two decades of magnitude, is cycle time reduction from 3 minutes to 25 seconds per unit tested.

Adjustable Helium Leak Standard

This Adjustable Helium Leak Standards by Helium Leak Testing, Inc. are the perfect Calibration Leak Standard for:

  • Mass Spectrometer Calibration
  • “Sniffer” probe standard
  • Vacuum pump speed measurements
  • Fits 1-1/8” QD, ¼” NPT or ISO fittings
  • Helium Leak Standard per ASME B&PV Code Section V, Article 10
  • Helium leak testing
  • Pressure/leak test standard
  • Automatic leak detection system calibration
  • Proving Helium concentration percentage

Blower (500CFM) Vacuum System

 
Blower (500CFM) Vacuum System Including : Gauge, Valves, Vacuum pump (60CFM) Electrical components plumbing and exhaust filter, inlet filter.
 

.