Equipment Sales
HLT 560 hydrogen and helium Leak detector
This Helium Leak detector is simple, user-friendly operation. Only Start/Stop
and Zero are required for standard operation, Menu driven, operating unit and
remote control in one unit.

Flapper Boxes
Features:
- Spring loaded, hinged top for
rapid loading of test specimens
- Standard connection flange: KF-25
(1 inch quick flange)
- Designed for testing of
hermetically sealed test specimens to MIL-STD 202 and 750
- Available in Aluminum and
Stainless Steel
- Standard Cavity Sizes:
| 2.275 in. |
.75 in. |
| 4.375 in. |
1.50 in. |
| 5.375 in. |
2.00 in. |
- Larger size available upon
request.
- Alternate connection flanges available upon request.
Helium Spray Gun/Nozzle for leak testing applications
Features:
- User friendly
- Complete and ready for use
- Connection to Regulator supplied
- Adjustable Helium Flow
- Pitol grip w/ trigger On/Off
action
- Non-Invasive Tip
- 10 ft. flexible hose standard
- Longer hose lengths available
- 1/4" NPT Adapter Supplied
HLT Pressurizing Helium Bomb Chamber
Features:
- 2 1/2 Gallon Capacity (.3125
cubic feet)
- 30 inch/0-75 PSIG Combination
Gauge
- Individual pressure and
Evacuation Valves (1/4 NPT)
- MIL-STD-202 / 750 Applications
- Rated for 30 inch Vacuum and 50
PSIG Pressure
- Portable
Pyrex Glass Bell jar
Features:
- Dimensions - 12x12 Inch
- Pyrex Glass
- W/ Gasket
- Scatter Shield and Base Plates available upon request
Q196 Leak Detector
Features:
- Sensitivity - Helium - 1x10
-5cc/sec
- R12 - 8x10 -3cc/sec
- CO2 - 1x1- -4 cc/sec
- Ar   - 1x10-4 cc/sec
- User friendly
- Display Units - cc/sec, cc/min,
cu. ft./ min, PPM
- Small, Robust and extremely
portable
- Response Time -< 1 second
- Operating Time - 9 hours per
charge
- Recharge Time - 19 hours from
total discharge
- Probe Length - 5 Ft
- Dimensions - Hand Unit :
3inx7inx1in Carrying Case 3in x 10in x 14'
- Weight - 1lb. 3.5 lbs.
Automated System: Multi-port Leak Detector System

Computer Controlled System
The multi-port system purpose is to leak check double enclosure pipe interconnections.
This system was designed to accommodate more than twenty different configurations
per customer request. Exchanging fixtures is fast and simple. A complete fixture
exchange and qualification would take no more than 10 minutes. The added value
of this system to our customer besides the ability able to enhance sensitivity
for two decades of magnitude, is cycle time reduction from 3 minutes to 25 seconds
per unit tested.
Adjustable Helium Leak Standard
This Adjustable Helium Leak Standards by Helium Leak Testing, Inc. are the perfect
Calibration Leak Standard for:
- Mass Spectrometer Calibration
- “Sniffer” probe standard
- Vacuum pump speed measurements
- Fits 1-1/8” QD, ¼” NPT or ISO fittings
- Helium Leak Standard per ASME B&PV Code Section V, Article 10
- Helium leak testing
- Pressure/leak test standard
- Automatic leak detection system
calibration
- Proving Helium concentration percentage
Blower (500CFM) Vacuum System
Blower (500CFM) Vacuum System Including : Gauge, Valves, Vacuum pump (60CFM)
Electrical components plumbing and exhaust filter, inlet filter.
.